Finally powered up the barn a few weeks ago. It was more than a year ago that I buried conduit between the house and barn, but all I did then was to run a fat extension cord through the pipe, and then ran one fluorescent fixture, radio, and all the tools off that. Yeah, the light would dim when I powered the big saw, but I never blew the breaker.
So, armed with a decade old How-To wiring book, and with a few websites like here and here (electricity is pretty easy to understand with just a little study), I went in with rolls of wire, sockets, switches, lights, boxes, wire nuts, grounding screws, etc. Yadda yadda. Having never worked in electrical panels or with breakers before, it was kinda exciting.
Here's the before and after of the subpanel I branched from, though I had already run one wire in (doubling up on an existing breaker, which is probably "legal"), at the time of the before pic:

I added a 15 amp breaker for the remote barn light, and ran the main 6/3 barn feed off a 50 amper.
And here's the sub-subpanel in the barn, before and after:

Sweet Cheeks helped me pull the 6/3 cable through the 80 feet of pipe, along with a 14/3 cable to run from a three way switch at the house to the light over the barn side door. The hardest part of hooking up the big wire was stripping the insulation off the ends. The 12/3 circuit (yellow cable, lower left) running off the double 20 breaker feeds a series of receptacles all around the inside of the barn, alternating like, to save running two sets of 12/2.
And it all works! No more over-loaded power strips and extension cords running everywhere.
And, while I was at it, I finished wiring up the front porch, a project left unfinished for a year and a half, and added a couple receptacles in the carport, too.